The original paper is in English. Non-English content has been machine-translated and may contain typographical errors or mistranslations. ex. Some numerals are expressed as "XNUMX".
Copyrights notice
The original paper is in English. Non-English content has been machine-translated and may contain typographical errors or mistranslations. Copyrights notice
Vues en texte intégral
95
Un affichage olfactif est un dispositif permettant de présenter des odeurs. Les caractéristiques temporelles de trois types d'affichages olfactifs, tels que celui basé sur la commutation à grande vitesse d'électrovannes, celui de bureau basé sur un atomiseur SAW et celui de type portable basé sur l'atomiseur SAW, ont été évaluées à l'aide de trois odorants avec des volatilités différentes. Le test sensoriel a révélé que les affichages olfactifs basés sur l'atomiseur SAW avaient des vitesses de présentation plus rapides que celles de commutation des électrovannes. Surtout, le portable avait une excellente caractéristique temporelle. Ces résultats dépendent en grande partie de la différence dans la méthode de diffusion des odeurs. Les données obtenues dans cette étude fournissent des connaissances de base lorsque nous élaborons des contenus olfactifs.
Masaaki ISEKI
Tokyo Institute of Technology
Takamichi NAKAMOTO
Tokyo Institute of Technology
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copier
Masaaki ISEKI, Takamichi NAKAMOTO, "Evaluation of Temporal Characteristics of Olfactory Displays with Different Structures" in IEICE TRANSACTIONS on Fundamentals,
vol. E104-A, no. 4, pp. 744-750, April 2021, doi: 10.1587/transfun.2020EAP1028.
Abstract: An olfactory display is a device to present smells. Temporal characteristics of three types of olfactory displays such as one based upon high-speed switching of solenoid valves, desktop-type one based on SAW atomizer and wearable-type one based on SAW atomizer were evaluated using three odorants with different volatilities. The sensory test revealed that the olfactory displays based on SAW atomizer had the presentation speeds faster than that of solenoid valves switching. Especially, the wearable one had an excellent temporal characteristic. These results largely depend on the difference in the odor delivery method. The data obtained in this study provides basic knowledge when we make olfactory contents.
URL: https://global.ieice.org/en_transactions/fundamentals/10.1587/transfun.2020EAP1028/_p
Copier
@ARTICLE{e104-a_4_744,
author={Masaaki ISEKI, Takamichi NAKAMOTO, },
journal={IEICE TRANSACTIONS on Fundamentals},
title={Evaluation of Temporal Characteristics of Olfactory Displays with Different Structures},
year={2021},
volume={E104-A},
number={4},
pages={744-750},
abstract={An olfactory display is a device to present smells. Temporal characteristics of three types of olfactory displays such as one based upon high-speed switching of solenoid valves, desktop-type one based on SAW atomizer and wearable-type one based on SAW atomizer were evaluated using three odorants with different volatilities. The sensory test revealed that the olfactory displays based on SAW atomizer had the presentation speeds faster than that of solenoid valves switching. Especially, the wearable one had an excellent temporal characteristic. These results largely depend on the difference in the odor delivery method. The data obtained in this study provides basic knowledge when we make olfactory contents.},
keywords={},
doi={10.1587/transfun.2020EAP1028},
ISSN={1745-1337},
month={April},}
Copier
TY - JOUR
TI - Evaluation of Temporal Characteristics of Olfactory Displays with Different Structures
T2 - IEICE TRANSACTIONS on Fundamentals
SP - 744
EP - 750
AU - Masaaki ISEKI
AU - Takamichi NAKAMOTO
PY - 2021
DO - 10.1587/transfun.2020EAP1028
JO - IEICE TRANSACTIONS on Fundamentals
SN - 1745-1337
VL - E104-A
IS - 4
JA - IEICE TRANSACTIONS on Fundamentals
Y1 - April 2021
AB - An olfactory display is a device to present smells. Temporal characteristics of three types of olfactory displays such as one based upon high-speed switching of solenoid valves, desktop-type one based on SAW atomizer and wearable-type one based on SAW atomizer were evaluated using three odorants with different volatilities. The sensory test revealed that the olfactory displays based on SAW atomizer had the presentation speeds faster than that of solenoid valves switching. Especially, the wearable one had an excellent temporal characteristic. These results largely depend on the difference in the odor delivery method. The data obtained in this study provides basic knowledge when we make olfactory contents.
ER -