Dans cet article, des données expérimentales sur les phénomènes de coupure de circuit sans arc dans les contacts électriques sont présentées. Un pont sombre qui est un pont non lumineux entre les contacts électriques est un facteur efficace pour la coupure de circuit sans arc. Une installation d'un système en porte-à-faux a été créée pour contrôler avec précision la position d'une électrode. En utilisant cette installation, des ponts sombres entre les contacts ont été créés et les ponts sombres ont été observés par un système de caméra microscopique.
Hiroyuki ISHIDA
Tohoku Bunka Gakuen University
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copier
Hiroyuki ISHIDA, "Non-Arcing Circuit Breaking Phenomena in Electrical Contacts due to Dark Bridge" in IEICE TRANSACTIONS on Electronics,
vol. E103-C, no. 5, pp. 238-245, May 2020, doi: 10.1587/transele.2019ECP5028.
Abstract: In this paper, experimental data of non-arcing circuit breaking phenomena in electrical contacts are presented. A dark bridge that is a non-luminous bridge between electrical contacts is an effective factor for the non-arcing circuit break. A facility of a cantilever system was established to precisely control a position of an electrode. By using this facility, dark bridges between contacts were made and the dark bridges were observed by a microscopic camera system.
URL: https://global.ieice.org/en_transactions/electronics/10.1587/transele.2019ECP5028/_p
Copier
@ARTICLE{e103-c_5_238,
author={Hiroyuki ISHIDA, },
journal={IEICE TRANSACTIONS on Electronics},
title={Non-Arcing Circuit Breaking Phenomena in Electrical Contacts due to Dark Bridge},
year={2020},
volume={E103-C},
number={5},
pages={238-245},
abstract={In this paper, experimental data of non-arcing circuit breaking phenomena in electrical contacts are presented. A dark bridge that is a non-luminous bridge between electrical contacts is an effective factor for the non-arcing circuit break. A facility of a cantilever system was established to precisely control a position of an electrode. By using this facility, dark bridges between contacts were made and the dark bridges were observed by a microscopic camera system.},
keywords={},
doi={10.1587/transele.2019ECP5028},
ISSN={1745-1353},
month={May},}
Copier
TY - JOUR
TI - Non-Arcing Circuit Breaking Phenomena in Electrical Contacts due to Dark Bridge
T2 - IEICE TRANSACTIONS on Electronics
SP - 238
EP - 245
AU - Hiroyuki ISHIDA
PY - 2020
DO - 10.1587/transele.2019ECP5028
JO - IEICE TRANSACTIONS on Electronics
SN - 1745-1353
VL - E103-C
IS - 5
JA - IEICE TRANSACTIONS on Electronics
Y1 - May 2020
AB - In this paper, experimental data of non-arcing circuit breaking phenomena in electrical contacts are presented. A dark bridge that is a non-luminous bridge between electrical contacts is an effective factor for the non-arcing circuit break. A facility of a cantilever system was established to precisely control a position of an electrode. By using this facility, dark bridges between contacts were made and the dark bridges were observed by a microscopic camera system.
ER -