Les réponses temporelles VI d'un relais électromagnétique conventionnel lors d'opérations de rupture de contact ont été mesurées. Dans un circuit de commutation conventionnel, une résistance de contact instable, des rebonds irréguliers et une mauvaise reproductibilité ont été confirmés. Grâce à un circuit de commutation de courant transitoire et à deux électrodes de contact aiguisées, les rebonds lors d'une opération de coupure ont été supprimés, et les changements instables de résistance de contact ainsi que la reproductibilité de l'opération de coupure ont également été améliorés.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copier
Noboru WAKATSUKI, Hiroshi HONMA, "Breaking Contact Phenomena of a Time-coordinated Non-arcing Relay" in IEICE TRANSACTIONS on Electronics,
vol. E91-C, no. 8, pp. 1206-1210, August 2008, doi: 10.1093/ietele/e91-c.8.1206.
Abstract: VI time responses of a conventional electromagnetic relay during breaking contact operations were measured. In a conventional switching circuit, unstable contact resistance, irregular bouncing, and poor reproducibility were confirmed. Using a transient current switch circuit and two sharpened contact electrodes, bouncing during a breaking operation was suppressed, and unstable contact resistance changes and reproducibility of breaking operation were also improved.
URL: https://global.ieice.org/en_transactions/electronics/10.1093/ietele/e91-c.8.1206/_p
Copier
@ARTICLE{e91-c_8_1206,
author={Noboru WAKATSUKI, Hiroshi HONMA, },
journal={IEICE TRANSACTIONS on Electronics},
title={Breaking Contact Phenomena of a Time-coordinated Non-arcing Relay},
year={2008},
volume={E91-C},
number={8},
pages={1206-1210},
abstract={VI time responses of a conventional electromagnetic relay during breaking contact operations were measured. In a conventional switching circuit, unstable contact resistance, irregular bouncing, and poor reproducibility were confirmed. Using a transient current switch circuit and two sharpened contact electrodes, bouncing during a breaking operation was suppressed, and unstable contact resistance changes and reproducibility of breaking operation were also improved.},
keywords={},
doi={10.1093/ietele/e91-c.8.1206},
ISSN={1745-1353},
month={August},}
Copier
TY - JOUR
TI - Breaking Contact Phenomena of a Time-coordinated Non-arcing Relay
T2 - IEICE TRANSACTIONS on Electronics
SP - 1206
EP - 1210
AU - Noboru WAKATSUKI
AU - Hiroshi HONMA
PY - 2008
DO - 10.1093/ietele/e91-c.8.1206
JO - IEICE TRANSACTIONS on Electronics
SN - 1745-1353
VL - E91-C
IS - 8
JA - IEICE TRANSACTIONS on Electronics
Y1 - August 2008
AB - VI time responses of a conventional electromagnetic relay during breaking contact operations were measured. In a conventional switching circuit, unstable contact resistance, irregular bouncing, and poor reproducibility were confirmed. Using a transient current switch circuit and two sharpened contact electrodes, bouncing during a breaking operation was suppressed, and unstable contact resistance changes and reproducibility of breaking operation were also improved.
ER -